| Reason | |||
|---|---|---|---|
| 0026043430018000 | Rp 1,119,990,000 | - | |
| 0801748682402000 | Rp 1,124,430,000 | - | |
| 0021435425064000 | - | - | |
| 0315692772418000 | - | - | |
PT Harapan Hadinata Universal | 06*2**4****47**0 | - | - |
| 0908885049504000 | Rp 1,113,330,000 | tidak lulus evaluasi teknis | |
| 0603509225402000 | Rp 1,100,238,216 | tidak lulus evaluasi teknis | |
| 0210798070411000 | - | - | |
| 0809521750501000 | - | - | |
PT Trans Telekomunikasi Indonesia | 09*4**2****64**0 | - | - |
| 0029611084541000 | - | - | |
CV Pilindo Mandiri Utama | 02*6**8****07**0 | - | - |
| 0811679885402000 | - | - | |
| 0630845543045000 | - | - | |
| 0759821218411000 | - | - | |
| 0025619719101000 | - | - | |
| 0315491431501000 | - | - | |
| 0312701535614000 | - | - | |
PT Sakya Berdikari Bersama | 05*2**9****57**0 | - | - |
CV Dahliana Perkasa | 08*9**2****17**0 | - | - |
| 0436082135447000 | - | - | |
| 0427170899422000 | - | - | |
| 0720111772008000 | - | - | |
PT Tri Star Pratama | 05*9**4****16**0 | - | - |
| 0737037556451000 | - | - | |
| 0026488718411000 | - | - | |
| 0610219800411000 | - | - | |
| 0032230138027000 | - | - | |
| 0729957266451000 | - | - | |
| 0025517004201000 | - | - | |
| 0718963275952000 | - | - | |
| 0021760483606000 | - | - | |
| 0746622968107000 | - | - | |
| 0024552820833000 | - | - | |
| 0032688103444000 | - | - | |
| 0750212045311000 | - | - | |
| 0029001443031000 | - | - | |
PT Larindo Mitra Abadi | 09*6**3****34**0 | - | - |
CV Artomoro Barokah | 05*0**7****31**0 | - | - |
Ninetynine Digital Niaga | 04*8**5****27**0 | - | - |
| 0022863377077000 | - | - | |
| 0027483502008000 | - | - | |
| 0413300641402000 | - | - | |
| 0901924746015000 | - | - | |
Tridaya Bakti Nusa | 03*8**8****17**0 | - | - |
| 0534417795429000 | - | - |
Pengembangan Sensor Monitoring Water Leak
DC Kemenkeu TA 2024
1. Gambaran Umum
Pusintek saat ini mengelola perangkat server di dalam Data Center (DC)
Kementerian Keuangan Jakarta dimana di dalamnya terdapat berbagai aplikasi seluruh
unit Eselon I di Kementerian Keuangan maupun Kementerian/ Lembaga lainnya.
Dalam mengelola layanan TIK, Pusintek mengadopsi Data Center Operation
Standart (DCOS) dimana salah satu prosesnya yaitu Monitoring, Reporting, Control
terhadap perangkat IT dan infrastruktur pendukung Pusat Data. Salah satu hal yang
dilakukan monitoring adalah terkait kebocoran air pada beberapa area yang memiliki unit
AC split atau tower, saat ini terdapat beberapa area yang belum miliki sensor air untuk
mendeteksi adanya kebocoran air atau kondensasi dari unit pendingin ruangan.
Dalam pekerjaan ini dibutuhkan penambahan sensor dan kelengkapannya agar
dapat dilakukan monitoring kebocoran air pada beberapa ruangan tersebut.
2. Kebutuhan
Berdasarkan hal-hal tersebut diatas, maka untuk kebutuhan penambahan sensor
monitoring water leak pada beberapa ruangan sebagai berikut:
Tabel 2. Daftar Ruangan yang Memerlukan Sensor
No Ruangan Lokasi Perangkat yang membutuhkan water leak
Lantai
1 Ruang Genset A 1 Sensor Leak Solar Genset A1 dan A2
Lantai
2 Ruang Genset B 1 Sensor Leak Solar Genset B1 dan B2
Lantai
3 MVMDB A 1 AC Split Wallmount 9000 btu/h
Lantai
4 MVMDB B 1 AC Split Wallmount 9000 btu/h
Lantai AC Tipe Wall Mounted VRF/VRV indoor
5 Ruang BMS-CCTV-SOC 1 unit - 2,8 KW
Lantai AC Tipe Ducted VRF/VRV indoor unit - 25
6 Ruang UPS IT A 2 KW
Lantai AC Tipe Ducted VRF/VRV indoor unit - 25
7 Ruang UPS IT B 2 KW
Lantai AC Tipe Ducted VRF/VRV indoor unit - 13
8 Ruang UPS ELC A 2 KW
Lantai AC Tipe Ducted VRF/VRV indoor unit - 13
9 Ruang UPS ELC B 2 KW
Lantai AC Tipe Surrounding Air Cassete VRF/VRV
10 Ruang Battrai Lithium A1 2 indoor unit - 10 KW
Lantai AC Tipe Surrounding Air Cassete VRF/VRV
11 Ruang Battrai Lithium A2 2 indoor unit - 10 KW
Lantai AC Tipe Surrounding Air Cassete VRF/VRV
12 Ruang Battrai Lithium B1 2 indoor unit - 10 KW
Lantai AC Tipe Surrounding Air Cassete VRF/VRV
13 Ruang Battrai Lithium B2 2 indoor unit - 10 KW
Ruang Power Room A (P Lantai
14 PDU A) 3 AC Split Wallmount 18000 btu/h
Ruang Power Room B (P Lantai AC Tipe Surrounding Air Cassete VRF/VRV
15 PDU B) 3 indoor unit - 10 KW
Lantai AC Tipe Wall Mounted VRF/VRV indoor
16 R. Staging 3 unit - 4,2 KW
Pada ruangan -ruangan yang memerlukan penambahan sensor dan beberapa perangkat
lainnya meliputi dan tidak terbatas pada hal hal sebagai berikut :
Jumlah
NO Item Jumlah
Ruangan
I Ruang Genset A & Genset B
1 Panel TTSIM-BBC-12VDC (Termasuk Baterai) 1 unit 2
: SECC 1.5mm steel with powder
* Enclosure coating
* Dimension : 250mm x 240mm x 85mm
* Weight : 3.5kg
* Input Power : 100-240VAC, Single Phase
Power
* Consumption : Max 2W
Visual
* Indication : Power LED
Charging LED
Discharging LED
Alarm LED
Audible
* Buzzer : 95dB output
: Main AC Fault Relay (Max rating:
* Relay Output 250VAC 1A)
Alarm Relay (Max rating: 250VAC 1A)
* Button : Acknowledge / Mute Button
Test Button
* Brand : Amerika
Jumlah
NO Item Jumlah
Ruangan
2 Sensor Oil Leak @15 meter 4 unit 2
3 Leader Cable, TTMLC 1 unit 2
4 End Termination, TTMET 1 unit 2
5 Hold Dwon Clip, TTHDC 2 unit 2
6 Tag TT-TAG 1 unit 2
Ruang MVMDB A & B, BMS-CCTV-SOC, UPS IT A & B, UPS ELC A & B, Ruang
Battery Lithium A1 & A2, Ruang Battery Lithium B1 & B2, Ruang Power
II
Room A (P PDU A), Ruang Power Room B (P PDU B), dan Power Room B (P
PDU B)
1 Panel TTSIM-BBC-12VDC (Termasuk Baterai) 1 unit 14
: SECC 1.5mm steel with powder
* Enclosure coating
* Dimension : 250mm x 240mm x 85mm
* Weight : 3.5kg
* Input Power : 100-240VAC, Single Phase
Power
* Consumption : Max 2W
Visual
* Indication : Power LED
Charging LED
Discharging LED
Alarm LED
* Audible Buzzer : 95dB output
: Main AC Fault Relay (Max rating:
* Relay Output 250VAC 1A)
Alarm Relay (Max rating: 250VAC 1A)
* Button : Acknowledge / Mute Button
Test Button
* Brand : Amerika
2 Sensor Water Leak, TT1000@15 meter 1 unit 14
3 Leader Cable, TTMLC 1 unit 14
4 End Termination, TTMET 1 unit 14
5 Hold Dwon Clip, TTHDC 2 unit 14
6 Tag TT-TAG 1 unit 14
III MATERIAL INSTALASI
1 Material instalasi 1 lot
3. Ruang Lingkup Pekerjaan
Ruang lingkup pekerjaan Pengembangan Sensor Monitoring Water Leak DC Kemenkeu
TA 2024 adalah:
a. Pengadaan Barang
Penyedia menyediakan perangkat yang memenuhi ketentuan spesifikasi teknis
sebagaimana tercantum dalam poin II.
b. Instalasi dan Konfigurasi
Penyedia melakukan instalasi dan konfigurasi terhadap perangkat yang telah diadakan
tersebut pada environment sistem yang ditentukan Pusintek termasuk integrasi dengan
tools DCIM. Integrasi sistem dengan SOP & MOP perangkat pendukung DC sesuai
kebutuhan DCOS.
c. Transfer of Knowledge
Penyedia melakukan transfer of knowledge kepada minimal 20 orang pegawai Pusintek
untuk 2 kali sesi training di lokasi training yang memadai yang disediakan oleh Penyedia
barang/jasa.
d. Pemberian Garansi dan Dukungan/Support
Penyedia barang memberikan garansi dan dukungan/support antara lain:
1) Garansi yang dimaksud dalam ketentuan ini adalah garansi dari Prinsipal yang
berkedudukan di Indonesia atau Distributor (dalam hal belum ada perwakilan
Prinsipal resmi di Indonesia) atau Partner yang ditunjuk oleh Prinsipal (dalam hal
belum ada Prinsipal atau Distributor yang berkedudukan di Indonesia);
2) Menyediakan garansi terhadap perangkat lunak yang ditawarkan minimal terhitung
sejak tanggal dokumen Berita Acara Serah Terima (BAST) ditandatangani hingga
minimal tanggal 31 Desember 2025;
3) Menyediakan dukungan dari penyedia barang/jasa untuk menjamin bahwa solusi
yang ditawarkan dapat berfungsi dengan baik, termasuk didalamnya penyediaan
tenaga ahli yang kompeten saat penanganan gangguan sewaktu-waktu atau sesuai
dengan Service Level Agreement dari pihak Pusintek;
4) Melakukan Preventive Maintenance tiap 4 bulan sekali selama 1 (satu) tahun
periode dukungan teknis setelah aktivitas go-live selama masa garansi;
5) Melakukan proses update, patching software, dan upgrade versi terbaru perangkat
lunak yang ditawarkan selama 1 (satu) tahun periode dukungan teknis setelah
aktivitas go-live selama masa garansi;
6) Memberikan dokumentasi atas update maupun upgrade software yang telah
dilakukan apabila diperlukan;
7) Memberikan dukungan teknis berupa reactive maintenance, penyesuaian
konfigurasi selama periode dukungan teknis setelah aktivitas go-live selama masa
garansi;