Pemeliharaan Datacenter Dan Drc

Basic Information
Type: Public Tender
Tender Code: 10018589000
Date: 12 March 2025
Year: 2025
KLPD: Kementerian Agraria dan Tata Ruang/BPN
Work Unit: Kantor Pusat Badan Pertanahan Nasional Republik Indonesia
Procurement Type: Jasa Lainnya
Method: Tender - Pascakualifikasi Satu File - Harga Terendah Sistem Gugur
Contract Type: Lumsum
Financial Information
Value (Nilai Pagu): Rp 5,103,027,000
Estimated Value (Nilai HPS): Rp 4,870,130,944
Winner (Pemenang): PT Wira Arta Telematika
NPWP: 020629556032000
RUP Code: 58076152
Work Location: Jl. Akses Tol Cimanggis, Wanaherang, Kec. Gn. Putri, Kabupaten Bogor, Jawa Barat 16966 - Bogor (Kab.)
Participants: 38
Applicants
Reason
0020629556032000Rp 4,378,136,000-
PT Sintesis Xtramile Solusindo
08*2**2****03**0--
0020766523047000--
Anp Cipta Inovasi
04*4**0****17**0--
PT Syncore Indonesia
03*2**7****43**0--
0024929424077000Rp 3,896,480,000Tidak memiliki pengalaman kontrak 1 tahun terakhir.
PT Trans Telekomunikasi Indonesia
09*4**2****64**0--
0723348025061000--
PT Kalpika Loka Persada
08*0**7****13**0--
0312111511428000--
0701697278003000--
PT Westindo Esa Perkasa
00*3**0****46**0--
0021435425064000--
0821010295447000--
0025344086017000--
Trisaka Multi Karya
0815508015411000--
0414374181603000--
0026043430018000--
PT Usaha Gedung Mandiri
00*0**1****93**0--
Mahakarya Bangun Jaya
04*7**6****48**0--
Cantika Dian Semesta
09*1**6****52**0--
0026488718411000--
0720111772008000--
0031250954044000--
PT Sigma Presisi Nusantara
10*0**0****24**4--
Terravision Geospasial Servis
01*8**3****49**0--
0854283876432000--
0011044518428000--
0029801917404000--
0669612608424000--
We Borneo Indonesia
09*2**3****07**0--
0023140650009000--
0839811882067000--
0025619719101000--
0753545607104000--
CV Cahaya Berkah
07*7**0****45**0--
0021436589016000--
0030471395039000--
Attachment
RUANG LINGKUP  PEKERJAAN                                                
Bagian-bagian yang menjadi ruang lingkup pemeliharaan meliputi :            
                                                                            
1. Lokasi Data Center Cikeas (pembelian perangkat tahun 2017)               
                                                                            
     No                    Lingkup Pekerjaan               Vol  Sat         
                                                                            
      I   Pemeliharaan Ruang DC, Sistem Rak dan Kabel Data                  
      1   Network Rack                                      4   unit        
      2   Server Rack                                       21  unit        
                                                                            
      3   Wallmount Rack                                    6   unit        
      4   Koneksi Fiber Optik dari Rack Server ke Rack Network 864 Core     
                                                                            
      5   Koneksi Fiber Optik dari Tiap Lantai ke Data Center 36 Core       
      6   Koneksi Fiber Optik dari Gedung Pusdiklat dan Asrama ke DC 24 Core
                                                                            
      7   Koneksi dan perapihan Kabel UTP Horizontal & Device to device 432 titik
      II  Pemeliharaan Sistem Elektrikal                                    
                                                                            
      A   Penerangan dan Socket Outlet                                      
      1   Socket Outlet Mobile 32A 1phase                  120  set         
                                                                            
      2   Socket Outlet Mobile 32A 3phase                   10  set         
      3   Socket Outlet 16A 1phase                          20  set         
                                                                            
      4   Socket Outlet 16A 1phase                          4   set         
      5   RLMO M1 + TL LED (Lantai 3)                       70  set         
                                                                            
      6   RLMO M1 + TL LED Emergency Light (Lantai 3)       15  set         
      7   RLMO M1 + TL LED (Lantai 2)                       14  set         
                                                                            
      8   RLMO M1 + TL LED Emergency Light (Lantai 2)       3   set         
      9   Exit Sign Lamp                                    3   set         
                                                                            
      B   Grounding System                                                  
      1   Grounding Sistem                                  1   lot         
                                                                            
          Grounding sistem untuk Genset                                     
          Grounding sistim untuk peralatan UPS, Battery dan Panel           
                                                                            
          Grounding bonding setiap Rack, Tray, Panel dan dibawah            
      C   PANEL LISTRIK Merk Gathergates                                    
          Panel Gedung Power                                                
                                                                            
      1   Indoor Freestanding Panel CPGS-A                  1   set         
      2   Indoor freestanding Panel LVMDP                   1   set         
                                                                            
          Panel Lantai 2                                                    
      3   Indoor freestanding Panel MSB A & B               2   unit        
                                                                            
      4   Indoor freestanding Panel UMSB A & B              2   unit        
          Panel Lantai 3                                                    
                                                                            
      5   Indoor freestanding Panel DB PAC A & B            2   unit        
      6   Indoor Wallmount Panel DB UTILITY A& B            2   unit        
                                                                            
      7   Indoor Wallmount Panel DB SERVER A& B             2   unit        
      8   Indoor Wallmount Panel DB ELEC A & B              2   unit        
                                                                            
      9   Panel ATS PAC PAC 1,2,3,4,5,6 & VRV 1,2           8   unit        
      10  Indoor Wallmount Panel PDU 1-3 A&B                6   unit        
                                                                            
      III Pemeliharaan Sistem Genset                                        
      1   Genset Data Center Kapasitas 800 kVA              1   unit        
      2   Genset Gedung Kapasitas 1000 kVA                  1   unit        
                                                                            
      3   Tangki harian kapasitas 500 liter                 1   unit        
      4   Tangki harian kapasitas 1000 liter                1   unit        
                                                                            
      5   Tangki bulanan kapasitas 5000 liter               2   unit        
      IV  Pemeliharaan UPS                                                  
                                                                            
      1   UPS Modular System Frame 200kVA Merk Eaton 9PHD + Battery 2 unit  
          Bank                                                              
      V   Pemeliharaan Sistem Elektronik dan Monitoring                     
                                                                            
      A   ENVIRONMENT  MONITORING  SYSTEM                                   
      1   Perangkat Integrated Monitoring System            1   set         
      B   ACCESS CONTROL  SYSTEM                                            
                                                                            
      1   Finger Print RFID, PoE, IP65 Vandal Resistant     11  unit        
      2   Exit Button & Emergency Breakglass                11  unit        
                                                                            
      3   Electromagnetic 600LBS EM Lock & U Bracket        10  unit        
      4   Electromagnetic 1200LBS EM Lock & U Bracket       8   unit        
                                                                            
      C   CCTV                                                              
      1   IP Camera                                         32  unit        
                                                                            
      2   NVR (Network Video Recorder)                      2   set         
      3   Switch 24 Port -PoE+ 180W                         2   unit        
                                                                            
      D   MONITOR  DISPLAY                                                  
          LCD Samsung KU7000 4K UHD                         4   unit        
                                                                            
      E   PERANGKAT  PC FOR NOC                                             
          Personal Computer All in One                      3   unit        
                                                                            
      VI  Pemeliharaan Sistem Pencegah Kebakaran                            
      A   LANTAI 2                                                          
                                                                            
          ELECTRICAL ROOM  & BATERY ROOM                                    
          VOLUME 16.5m x 4.5m x 5.8m = 430.65m³ 3 LAYERS                    
          PROTECTION                                                        
          NOVEC 1230 EQUIPMENT                                              
                                                                            
      1   NOVEC 1230 Cylinder & Valve Assy, Capacity 900lb  1   unit        
      2   NOVEC 1230 Agent                                 623  lbs         
                                                                            
      3   Cylinder Strap #900                               2   unit        
      4   Electric Control Head                             1   unit        
                                                                            
      5   Pressure Switch                                   1   unit        
      6   Nozzle                                            9   unit        
                                                                            
          DETECTION EQUIPMENT  KIDDE FENWAL                                 
      1   Aries Control Unit                                1   unit        
                                                                            
      2   Suppression Key Maintenance Switch                1   unit        
      3   Intelligent Photoelectric Smoke detector w/base   15  unit        
      4   AI Monitor Module (ACID)                          3   unit        
                                                                            
      5   Addressable Manual Pull Station                   1   unit        
      6   Abort Station                                     1   unit        
                                                                            
      7   Multitone w/strobe                                2   unit        
      8   Fire Alarm Bell                                   1   unit        
                                                                            
      9   “EVACUATED AREA” Sign Lamp                        2   unit        
      10  “GAS DISCHARGE DO NOT ENTER” Sign Lamp            1   unit        
                                                                            
          LANTAI 3                                                          
      B   SERVER ROOM  , UTILITY ROOM 1, ENTERANCE ROOM                     
                                                                            
          VOLUME 1.460,73m³ 3 LAYERS PROTECTION                             
          NOVEC 1230 EQUIPMENT                                              
                                                                            
      1   NOVEC 1230 Cylinder & Valve Assy, Capacity 900lb  3   unit        
      2   NOVEC 1230 Agent                                 2,11 lbs         
                                                                            
      3   Cylinder Strap #900                               6   unit        
      4   Electric Control Head                             1   unit        
                                                                            
      5   Pressure Operated Control Head                    2   unit        
      6   Master Cylinder Adapter Kit                       1   unit        
                                                                            
      7   Male Connector                                    2   unit        
      8   Pressure Switch                                   3   unit        
                                                                            
      9   Nozzle                                            18  unit        
          DETECTION EQUIPMENT                                               
      1   Suppression Key Maintenance Switch                1   unit        
                                                                            
      2   Remote Releasing Module                           1   unit        
      3   Intelligent Photoelectric Smoke Detector w/base   28  unit        
                                                                            
      4   Intelligent Photoelectric Smoke Detector w/base (u/R. NOC) 3 unit 
      5   AI Monitor Module                                 5   unit        
                                                                            
      6   AO Control Module                                 2   unit        
      7   Addressable Double Action Manual Pull Station     1   unit        
                                                                            
      8   Suppression Abort Station                         1   unit        
      9   Alarm Signal Module                               2   unit        
                                                                            
      10  Multitone w/strobe Fire                           3   unit        
      11  Alarm Bell                                        3   unit        
                                                                            
      12  “EVACUATED AREA” Sign Lamp                        3   unit        
      13  “GAS DISCHARGE DO NOT ENTER” Sign Lamp            3   unit        
                                                                            
     14   PENIMBANGAN                                                       
          Tabung Novec 1230                                 4   unit        
                                                                            
     VII  Pemeliharaan Sistem Pendingin                                     
      A   PRECISION AIR CONDITIONING                                        
                                                                            
      1   PAC Cooling Unit 60 kW Merk Libert                4   unit        
      B   COMFORT  AIR CONDITIONING                                         
      1   AC VRV IV R410A Daikin untuk Lantai 2 :                           
                                                                            
          - Outdoor Unit, Kap 154.000 Btu/h                 1   Unit        
          - Indoor Unit, Kap 54.600 Btu/h                   1   Unit        
                                                                            
          - Indoor Unit, Kap 95.500 Btu/h                   1   Unit        
          - Refinet Joint                                   1   Unit        
                                                                            
      2   AC VRV IV R410A Daikin Lantai 3 :                                 
          - Outdoor Unit, Kap 76.000 Btu/h                  1   Unit        
                                                                            
          - Indoor Unit, Kap 38.200 Btu/h                   2   Unit        
                                                                            
                                                                            
                                                                            
2. Lokasi Disaster Recovery Center Jakarta (pembelian perangkat tahun 2013) 
                                                                            
     No. Lingkup Pekerjaan                                Vol  Sat          
      I  Pemeliharaan Ruang Data Center                                     
                                                                            
         Rack Server                                       16  unit         
      II Pemeliharaan Sistem Elektrikal                                     
                                                                            
      1  Panel LVMDP 50x150x60cm                           1   unit         
         Pilot Light (LED) ø 22mm, 220Vac, AD22-22xDS ( 6 unit) Miniature   
         Fuse Link 10 x 38 x 2A, 3OZM3802 (12 unit) Fuse RT-18-1PL,         
                                                                            
         30ZFHR8L (6 unit)                                                  
         Digital Power Meter                                                
         CT 400/5A, Cl 0,5 ( 5A ), ref HG 40-400 (3 unit) MCCB 4P 160-400 A 
                                                                            
         36KA + Micrologic 2.3                                              
         Mtr MT400/630 for NSX 400/630, 220/240VAC, 50/60Hz UVT (MN)        
         220/240VAC, 50/60Hz                                                
                                                                            
         ATS Open Transition 400A c/w Controller                            
                                                                            
      2  Panel PKG Genset 70x160x60                        1   unit         
         Pilot Light (LED)ø 22mm, 220Vac (6 unit)                           
                                                                            
         Miniature Fuse Link 10 x 38 x 2A, 3OZM3802 (18 unit) Fuse RT-18-   
         1PL, 30ZFHR8L (9 unit)                                             
                                                                            
         Digital Power Meter (2 unit)                                       
         CT 400/5A, Cl 0,5 ( 5A ), ref HG 40-400 (6 unit)                   
                                                                            
         MCCB 4P 160-400 A 36KA + Micrologic 2.3 (2 unit) Mtr MT400/630     
         for NSX 400/630, 220/240VAC (2 unit)                               
         Shunt Trip ( MX ) 220/240VAC, 50/60 Hz (2 unit) MCCB 4P 160-400 A  
                                                                            
         36KA + Micrologic 2.3                                              
         Modul AMF (2 unit)                                                 
                                                                            
         CT 400/5A, Cl 0,5 ( 5A ), ref HG 40-400 (8 unit)                   
         Automatic Battery Charger BC 0624, 24VDC/6A (2 unit)               
                                                                            
      3  Panel MDP Data Center 50X105X30                   1   unit         
         Pilot Light (LED) ø 22mm, 220Vac (3 unit)                          
         Miniature Fuse Link 10 x 38 x 2A, 3OZM3802 (12 unit) Fuse RT-18-   
                                                                            
         1PL, 30ZFHR8L (6 unit)                                             
         Digital Power Meter                                                
                                                                            
         CT 400/5A, Cl 0,5 ( 5A ), ref HG 40-400 (3 unit) MCCB 3P 400A 36KA 
         MCCB 4P/3T 112-160 A 25KA + TM160D (2 unit) MCB 3P 63A,            
                                                                            
         iC60N, Kurva C, 10 KA (3 unit) MCB 1P 16A, iC60N, Kurva C, 10 KA   
         (6 unit)                                                           
      4  Panel SDP I/O UPS 60X125X30                       1   unit         
                                                                            
         Pilot Light (LED) ø 22mm, 220Vac (12 unit)                         
         Miniature Fuse Link 10 x 38 x 2A, 3OZM3802 (24 unit)               
         Fuse RT-18-1PL, 30ZFHR8L (12 unit)                                 
                                                                            
         Digital Power Meter                                                
         CT 250/5A, Cl 0,5 ( 5VA ), ref HG 30l-250 (3 unit)                 
                                                                            
         MCCB 3P/3T 175-250 A 25KA + TM160D                                 
         MCCB 3P/3T 112-160 A 25KA + TM160D                                 
                                                                            
         MCCB 4P/3T 112-160 A 25KA + TM160D                                 
         MCCB 4P/3T 112-160 A 25KA + TM160D                                 
                                                                            
         MCB 3P 32A, iC60N, Kurva C, 10 KA                                  
         MCB 1P 32A, iC60N, Kurva C, 10 KA (4 unit)                         
                                                                            
         MCB 1P 16A, iC60N, Kurva C, 10 KA (8 unit)                         
         MCB 1P 10A, iC60N, Kurva C, 10 KA                                  
                                                                            
         MCCB 3P/3T 112-160 A 25KA + TM160D                                 
         MCCB 4P/3T 112-160 A 25KA + TM160D                                 
                                                                            
         MCCB 4P/3T 112-160 A 25KA + TM160D                                 
         MCB 3P 32A, iC60N, Kurva C, 10 KA                                  
                                                                            
         MCB 1P 32A, iC60N, Kurva C, 10 KA                                  
         MCB 1P 16A, iC60N, Kurva C, 10 KA (11 unit)                        
                                                                            
         MCB 1P 10A, iC60N, Kurva C, 10 KA (3 unti)                         
      5  Panel Battery 60X60X25                            2   unit         
                                                                            
         MCCB 2P 250A 36KA                                                  
      6  Lighting                                          25  unit         
         Downlight Essential 13W (15 unit)                                  
                                                                            
         RM 120x60 2x32W ( 10 unit)                                         
      7  Cee-form 32A. 1P legrand (under Raised floor)     32  unit         
                                                                            
      8  Cee-form 32A. 3P legrand (under Raised floor)     3   unit         
     III Pemeliharaan UPS                                                   
                                                                            
      a  EATON 9E UPS 100 KVA + Battery                    2   unit         
     IV  Pemeliharaan Genset                                                
                                                                            
      1  Perkins Stamford Genset 250 KVA                   2   Unit         
      2  Tangki Bahan bakar 5000 liter                     1   Unit         
                                                                            
      V  Pemeliharaan Sistem Elektronik dan Monitoring                      
      1  Unitron Enviromux EMSa Infinity CCTV System       1    lot         
         Indoor Dome IP Camera (10 unit) NVR Server + Monitor               
                                                                            
         Suprema Access Control System                                      
      2  Finger Print EM Lock Push Button                  1    lot         
                                                                            
      3  Emergency Break Glass                             4    set         
     VI  Pemeliharaan Sistem Pencegah Kebakaran                             
                                                                            
      1  Fenwal FM 200 Fire Protection Fenwalnet 6000 Control Panel FM 200 1 lot
         Cylinder 350 lbs Nozzle ( 4 unit)                                  
                                                                            
         Fire Detector (8 unit)                                             
         Suppression Abort Station (1 unit)                                 
                                                                            
         Double Action Manual Pull Station (1 unit)                         
         Multitone w/Strobe ( 2 unit) Fire Alarm Bell (1 unit)              
                                                                            
         " EVACUATE AREA " Sign Lamp ( 2 unit)                              
         " GAS DISCHARGE DO NOT ENTER " Sign Lamp (2)                       
                                                                            
         PENIMBANGAN                                       1   Unit         
         FENWAL  FM200                                                      
     VII Pemeliharaan Sistem Pendingin                                      
                                                                            
      1  Liebert PEX P2060 PAC                             3   unit         
      2  Sharp AC SPLIT 1 pk                               2   unit         
                                                                            
                                                                            
Ruang lingkup pekerjaan Pemeliharaan Fasilitas pendukung Data Center dan Disaster Recovery Center meliputi
                                                                            
:                                                                           
                                                                            
  1. Pemeliharaan ruang, Sistem Rak dan Kabel Data,                         
     Pemeliharaan kondisi kebersihan dan kerapihan Data Center dan Disaster Recovery Center dengan
                                                                            
     melakukan hal-hal sebagai berikut :                                    
      a) Peletakan perangkat agar tetap berada pada lokasi yang sudah ditentukan.
                                                                            
      b) Memastikan tidak ada barang-barang yang bukan perangkat Data Center dan Disaster Recovery
                                                                            
        Center berada didalam ruang Data Center dan Disaster Recovery Center .
      c) Memastikan keamanan Data Center dan Disaster Recovery Center, rack selalu dalam kondisi aman
                                                                            
        dan terkunci serta akses keluar masuk harus selalu menggunakan fingerprint dan terpantau CCTV
        aktif.                                                              
                                                                            
      d) Menjaga kebersihan ruangan termasuk raised floor dan bagian bawah raised floor dari debu dan
        kotoran lainnya.                                                    
                                                                            
      e) Pengecekan sirkulasi udara dibawah raised floor dan rack.          
                                                                            
      f) Pengecekan suhu dan kelembaban udara normal dalam ruang Data Center dan Disaster Recovery
        Center pada kisaran 19’C sampai dengan maksimal 22’C dan kelembaban udara antara 40% sampai
                                                                            
        dengan 60%.                                                         
      g) Menjaga dan memperbaiki bila ada kebocoran air diruangan DC        
                                                                            
      h) Melakukan perbaikan pada dinding yang retak                        
      i) Melakukan perbaikan pada dak yang bocor dan rembes                 
                                                                            
      j) Melakukan perbaikan pada plafon yang rusak.                        
                                                                            
      k) Pengecekan kerapihan dan labeling, serta pengkabelan baik itu kabel data ataupun kabel listrik
        sesuai standar.                                                     
                                                                            
      l) Pengecekan koneksi jaringan kabel data.                            
  2. Pemeliharaan Sistem Elektrikal                                         
                                                                            
     Menjaga pasokan listrik ke perangkat Data Center dan Disaster Recovery Center dengan melakukan
                                                                            
     pemeliharaan Panel-panel listrik di ruang Data Center dan Disaster Recovery Center dan pemeliharaan
     Lighting serta Outlet Power dengan melakukan hal-hal sebagai berikut : 
                                                                            
      a) Melakukan pengukuran Tegangan dan Arus pada masing-masing Panel.   
      b) Melakukan Pengecekan dan perbaikan serta penggantian suku cadang (spare part) Panel bila
                                                                            
        mengalami kerusakan.                                                
                                                                            
      c) Melakukan kalibrasi dan setting untuk komponen yang memerlukan kalibrasi.
      d) Melakukan Thermal scanning Check pada masing-masing Panel          
                                                                            
      e) Memeriksa kekencangan baut dan konektor serta melakukan perbaikan bila di temukan yang kurang
        kencang.                                                            
                                                                            
      f) Melakukan pembersihan Panel.                                       
                                                                            
      g) Membuat laporan update single line diagram Panel dan Pelabelan.    
      h) Melakukan Pengecekan kondisi fisik dan perbaikan serta penggantian komponen/perangkat lighting
                                                                            
        dan power outlet apabila rusak.                                     
      i) Melakukan pembersihan lighting dan power outlet                    
                                                                            
                                                                            
  3. Pemeliharaan System Genset                                             
                                                                            
     Menjaga pasokan listrik cadangan yang bersumber dari Genset dengan melakukan perawatan pada
                                                                            
     perangkat yang meliputi meliputi :                                     
      a) Memeriksa dan melakukan uji secara berkala untuk memastikan fungsi beralih otomatis pada genset
                                                                            
        dapat berfungsi dengan baik apabila pasokan listrik dari PLN terputus;
      b) Memeriksa secara visual kondisi fisik Genset, apakah terdapat kebocoran, over noise (vibration),
                                                                            
        dan korosi;                                                         
                                                                            
      c) Membersihkan bagian body engine dan air filter;                    
      d) Melakukan pengukuran ketinggian level, yaitu pada air radiator coolant, lube oil, dan fuel tank;
                                                                            
      e) Memeriksa tegangan v-belt.                                         
  4. Pemeliharaan UPS                                                       
                                                                            
     Pemeliharaan UPS agar tetap berfungsi dengan baik yang meliputi:       
      a) Menjaga pasokan listrik cadangan yang bersumber dari UPS dengan melakukan perawatan pada
                                                                            
        perangkat yang meliputi :                                           
      b) Memeriksa nilai tegangan, arus, frekuensi, daya, beban, backup time dan kapasitas UPS apakah
                                                                            
        masih dalam batas standar operasi.                                  
                                                                            
      c) Kalibrasi pembacaan tegangan pada display UPS, dibandingkan dengan alat ukur.
      d) Melakukan pengujian UPS dan pengujian beban pada battery.          
                                                                            
      e) Pengujian UPS meliputi test Display untuk memastikan apakah display berfungsi dengan baik.
      f) Membersihkan kotoran / debu terutama pada Fan dan Heat Sink, permukaan block battery, dan
                                                                            
        cabinet.                                                            
                                                                            
      g) Pemeriksaan secara visual keseluruhan UPS dan battery. Mulai dari keadaan masing - masing board,
        koneksitas antar board dan pemeriksaaan apakah ada bad contact. Juga pemeriksaan battery secara
                                                                            
        fisik;                                                              
                                                                            
                                                                            
  5. Pemeliharaan Sistem Elektronik dan Monitoring                          
                                                                            
     Pemeliharaan peralatan-peralatan elektronik dan monitoring sebagai system keamanan Data Center dan
     Disaster Recovery Center seperti Environment Monitoring System (EMS), CCTV System dan Access
                                                                            
     Control System yang meliputi :                                         
      a) Pembersihan dari debu dan kotoran setiap perangkat elektronik dan sensor
                                                                            
      b) Memeriksa kondisi fisik seluruh peralatan elektronika.             
                                                                            
      c) Memeriksa History Log Report pada aplikasi untuk memeriksa histori kejadian sebagai indikator
        jika terjadi sesuatu di ruang Data Center dan Disaster Recovery Center .
                                                                            
      d) Memeriksa kondisi probe/sensor EMS apakah sesuai pada posisi dan berfungsi dengan baik.
      e) Melakukan pemeliharaan Camera CCTV dengan membersihkan bagian kaca lensa dan
                                                                            
        mengembalikan arah Camera ke posisi semula.                         
      f) Membersihkan Monitor Display.                                      
                                                                            
      g) Memeriksa kapasitas penyimpanan data video record pada server cctv.
                                                                            
      h) Melakukan pemeliharaan Access Door pada unit Finger Print dan EM Lock.
      i) Melakukan pemeliharaan EM Lock di setiap pintu dan melakukan penyetelan posisi EM lock jika
                                                                            
        diperlukan.                                                         
                                                                            
                                                                            
  6. Pemeliharaan Sistem Pencegah Kebakaran                                 
                                                                            
     Pemeliharaan Fire Protection System ( NOVEC 1230 ) agar tetap berfungsi dengan baik yang meliputi
     :                                                                      
                                                                            
      a) Pemeriksaan awal kondisi system, baik system deteksi, Hardware and auxiliary equipment dan
        penyesuaian dengan lay out awal.                                    
      b) Simulation Detection test system, meliputi Detector, Alarm Bell, Horn Stobe, Module, dan Control
                                                                            
        Panel.                                                              
      c) Pengechekan Mechanical Perangkat, seperti check Electric control head, Piping, hose dan pressure
                                                                            
        switch.                                                             
      d) Pemeriksaan tekanan dalam cylinder.                                
                                                                            
      e) Penimbangan cylinder.                                              
                                                                            
                                                                            
  7. Pemeliharaan Sistem Pendingin                                          
                                                                            
     Pemeliharaan terhadap perangkat pendingin ruangan yang meliputi :      
      a) Melakukan monitoring history Log PAC untuk mengetahui histori kejadian sebagai indikator jika
                                                                            
        terjadi sesuatu pada sisten pendingin ruang Data Center dan Disaster Recovery Center .
                                                                            
      b) Pengukuran kondisi sumber listrik, tegangan, arus listrik dan frekuensi.
      c) Pemeriksaan dan testing pada system : Cooling, De-Humidification, Heating
                                                                            
      d) Setting dan Kalibrasi pada control system                          
      e) Melakukan Pengecekan baik unit Indoor maupun unit Outdoor dan penggantian suku cadang (spare
                                                                            
        part) jika diperlukan.                                              
                                                                            
      f) Pembersihan rutin pada bagian condenser, drainage system dan filtering.
  8. Laporan pemeliharaan yang meliputi :                                   
                                                                            
      a) Laporan Pemeriksaan awal kegiatan yang dibuat 2 (dua) rangkap, berisikan Laporan Performance
        Data Center dan Disaster Recovery Center dan kondisi awal.          
                                                                            
      b) Laporan Pemeliharaan Bulan Pertama yang dibuat 2 (dua) rangkap     
                                                                            
      c) Laporan kegiatan Pemeliharaan Data Center dan Disaster Recovery Center Bulan Pertama.
      d) Laporan Pertengahan Tahun Kegiatan dibuat 2 (dua) rangkap          
                                                                            
      e) Laporan Akhir dibuat rangkap 3 (tiga) berisi laporan hasil akhir Kegiatan.
Tenders also won by PT Wira Arta Telematika
Authority
20 February 2024Pemeliharaan Datacenter Dan DrcKementerian Agraria dan Tata Ruang/BPNRp 5,971,800,000
10 May 2023Pemeliharaan Perangkat Data Center Bpkp (Ups, Ac, Data Storage, Fire Suppression System Etc)Badan Pengawasan Keuangan Dan PembangunanRp 1,864,800,000
27 December 2023Pemeliharaan Perangkat Pendukung Data Center MmuKementerian Dalam NegeriRp 1,620,963,000
23 September 2022Pemeliharaan Pemutakhiran Jaminan Layanan Penggunaan Dan Pemeliharaan Perangkat Keamanan Jaringan KomputerKementerian Sekretariat NegaraRp 922,415,000
14 September 2022Pengadaan Lisensi Next Generation Firewall (Ngfw) Checkpoint Dan Network Monitoring System SolarwindsSekretariat KabinetRp 860,908,000
23 May 2022Pemeliharaan Pemutakhiran Jaminan Layanan Penggunaan Dan Pemeliharaan Server StorageKementerian Sekretariat NegaraRp 674,383,000
18 April 2018- Peremajaan Switch ShaftKementerian PerindustrianRp 633,880,000
11 April 2018- RouterKementerian PerindustrianRp 627,780,000
15 October 2021Pengadaan Lisensi Dan Support Next Generation Firewall (Ngfw)Sekretariat KabinetRp 400,000,000
6 November 2020Pemutakhiran Jaminan Layanan (Ngfw License)Sekretariat KabinetRp 346,415,620